Battery Management System
Key Features
- Intelligent passive balancing
- Designed for AIS 156 & ISO 26262
- Life cycles tracking
- Battery Health monitoring
- Data monitoring and analysis on cloud
- Battery Live Location Updates
- Cloud Connectivity - Through BLE on board or 4G add-on device
- Mobile app for user
- User Battery Usage Data
- Battery Monitoring Platform (For Manufacturers and Operators)
- Battery Tracking
- Battery Immobilisation
- SoC LED Indication
Key Technical Specifications
General Specifications
Nominal Rtaing | 48V |
---|---|
Operating Voltage Range | 30V-63V |
Peak Discharge Current | 2C |
Operating Current | Upto 30A/td> |
Series Cell Support | 15 series |
Switching Type | MOSFET Control |
No. of Cells | 10 to 15 Cells |
No. of Cells | 10 to 15 Cells |
Pack Voltage Measurement Accuracy | +/- 2mV |
Single Cell Voltage Accuracy | +/- 2mV@30°C |
Cell Temperature | + / - 1°C @ -10 TO 90°C |
Current Measurement Input Shunt Range | 200 m V |
Current Measurement Input Shunt Accuracy | + / - 0.5 m V @ -10 TO 90°C |
Cell Voltage Detection (Min) | 0V |
Cell Voltage Detection (Max) | 6V |
Cell Protection (Over Voltage) | 4.17V |
Cell Protection (Under Voltage) | 3.1V |
Cell Balancing Topology | PASSIVE BALANCING |
Cell Balancing Current | 89mA@4.2V |
ON-BOARD Current measurement | YES-AUTO CALIBRATED ONBOARD SHUNT |
ON-BOARD Power Disconnect | YES |
ON-BOARD Pre-Charge Control | YES |
Supported CAN Communication Type | CAN 2.0 / 11 BIT AND 29 BIT ID'S |
Supported CAN Communication Speed | 125KB,250KB,500KB |
Supported CAN Communication Ports | 1 |
Cell Voltage Typical Sampling Time | 250ms |
Range Of Temperature Measurements | -10 TO 90ºC |
Temperature Sensor Channels | 14 CHANNELS 2 on-board, 12 external |
BMS Dimension | 140 mm×117 mm×23 mm |
Number Of Voltage Channels | 15 Channels |
Maximum Current Continuous Without Active Cooling | 30 A |
Peak Current | 2C for 3 SECONDS |
Bi-Directional Current Protection | YES |
Communication Models | CAN/Rs/BLE (Configurable) |
External General Purpose I/O's | 2 |
Charge Control Interfaces | CAN/RS485 |